6ES7155-6AU01-0CN0 match
6ES7155-6AU01-0CN0 is treated as the exact part-number anchor for this record.
Siemens / 6ES7155-6AU01-0CN0
Siemens 6ES7155-6AU01-0CN0 is an RFQ sourcing record. IndGear confirms source, condition, lead time, and quote terms before approval.
Siemens 6ES7155-6AU01-0CN0 fieldbus communication module is a fieldbus communication module in the PLC Modules category. This page turns the SKU record into a source-check brief before quote approval.
6ES7155-6AU01-0CN0 is treated as the exact part-number anchor for this record.
Siemens identity and structured values are kept together for buyer review.
Verified USD reference exists, but final quote terms stay RFQ-confirmed.
Quantity, destination, condition, revision, documents, and machine context make the quote review cleaner.
Siemens 6ES7155-6AU01-0CN0 is an RFQ sourcing record. IndGear confirms source, condition, lead time, and quote terms before approval.
Specification depth: verified specsUse these guides to tighten exact part identity, condition language, source evidence, replacement risk, and RFQ inputs before treating a product record as purchase-ready.
SIMATIC order-code, family, and replacement checks.
Replacement sourcingReplacement module checks before approving fit.
Cross-reference guideCandidate replacement review before RFQ approval.
RFQ checklistCore fields needed for a cleaner quote review.
Siemens 6ES7155-6AU01-0CN0 is maintained as a SIMATIC PLC module for PLC cabinet maintenance, I/O expansion, and controller-platform spare matching.
It is grouped with SIMATIC industrial automation module records so buyers can compare like-for-like spares instead of treating it as an anonymous import line.
The card is treated as rich because source-backed structured data supports the identity and specification depth. Current structured facts include communication protocol PROFINET compatible system SIMATIC automation system
mounting control cabinet / PLC rack series SIMATIC S7 family. USD price context is available as a reference observation, while final commercial terms still require RFQ confirmation.
Before approval, confirm controller family, I/O signal type, revision or firmware, terminal layout, quantity, preferred condition, and destination country.
The record does not claim verified channel relationship, confirmed allocation, warranty, lead time, or final compatibility without operations review.
Structured values are preserved from the current record. Confirm ratings, revision, and compatibility before approval.
| Manufacturer part number | 6ES7155-6AU01-0CN0 |
|---|---|
| Product type | fieldbus communication module |
| Product family | SIMATIC industrial automation module |
| Series | SIMATIC S7 family |
| Function | PLC, I/O, or automation-system module |
| Mounting | control cabinet / PLC rack |
| Dimensions | 50 x 117 x 74 mm |
| Approvals | FM |
| communication protocol | PROFINET |
| Compatible system | SIMATIC automation system |
| weight | 120 g |
Source records help the RFQ desk review identity, price context, and risk. They do not create confirmed allocation, channel-status, warranty, or quote-term promises.
Siemens-owned product detail URL found in the official product sitemap with exact SKU match
Source 1Source 2Distributor or surplus listing used for sourcing context
Source 1Source 2Search-result evidence is retained for RFQ review only
Raw supplier/import notes are preserved for manager review before quote approval.
Open the Siemens lane to compare active records, verified price coverage, specification depth, and RFQ-ready categories.
Category hubCompare related PLC Modules records, source depth, verified-price coverage, and selection risks before approving a substitute.
Source policySee how IndGear separates manufacturer references, datasheets, marketplace observations, supplier quotes, and import notes.
Warranty reviewReview why warranty, RMA, and return paths stay tied to the approved source, condition, and written quote.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Include quantity, destination country, required condition, acceptable alternates, revision or firmware needs, machine context, and any nameplate photo, BOM line, datasheet, or failed-unit notes.
Use the PLC Modules category hub and similar-record links on this page to compare related SKUs, source depth, specification coverage, and RFQ requirements.
This record currently has 9 source records. Source evidence is classified for identity, specification, pricing, condition, and manual-review value before it becomes a quote claim.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported channel-status claim is made here. IndGear operates as an independent supplier marketplace unless a specific relationship is verified in writing.
The RFQ desk confirms identity, source route, final USD quote, lead time, warranty terms, and shipping before your team approves the order.