3 records
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3Sick / UM18-51115
Use Sick UM18-51115 (sensor or switch component) for machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type, connector, and supply voltage with buyer documents before quote approval.
Sick UM18-51115 is listed as a Sensors sensor or switch component record for SKU-led sourcing. The current record shows condition to confirm, requires price confirmation, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.
Sick UM18-51115 is maintained as a sensor or switch component in the IndGear data layer. This update replaces generic import wording with a clearer procurement category, buyer-confirmation checklist, and safe source context. The record currently relies on supplier/import evidence, so buyer documents are required before final approval. The page is RFQ context only and does not claim stock, warranty, lead time, authorized distribution, or final compatibility. Before quoting or approving a replacement, confirm sensing target/range, output type, connector/cable type, mounting constraints, quantity, condition preference, destination country.
| series | Sick sensor family |
|---|---|
| current | <= 500 mA |
| voltage | DC 10 V ... 30 V |
| function | machine sensing, feedback, or measurement |
| descriptor | industrial sensor |
| dimensions | 18 mm x 18 mm x 73.3 mm |
| resolution | >= 0.08 mm |
| source brand | SICK |
| response time | 32 ms |
| product family | Sick sensor family |
| housing material | Metal, plastic (nickel-plated brass, PBT, ultrasonic transducer: polyurethane foam, glass epoxy resin) |
| connection method | Male connector, M12, 5-pin |
| protection rating | IP65 / IP67 |
| safe product type | sensor or switch component |
| source confidence | high |
| supplier keywords | SICK, Датчик ультразвуковой UM18-51115 6028974, Датчик, ультразвуковой, UM18-51115, 6028974 |
| temperature range | –25 deg C ... +70 deg C |
| validated category | Sensors |
| product designation | UM18-51115 |
| verified spec notes | SICK structured specs were parsed from exact SICK-owned FactFinder product records and product-page article numbers. No stock, warranty, authorized-distributor, lead-time, replacement, or compatibility claim is inferred. |
| official product url | https://www.sick.com/us/en/p/pn6028974 |
| verified spec fields | alternate_part_numbers, connection_method, current, dimensions, housing_material, manufacturer_part_number, product_designation, protection_rating, resolution, response_time, temperature_range, voltage |
| verified spec method | a_plus_plus_sick_factfinder_specs_batch_v1 |
| official source brand | Sick |
| verified spec api url | https://www.sick.com/api/fact-finder/search/enUS-sick?query=6028974&showPermutedSearchParams=false |
| alternate part numbers | 6028974 |
| official product title | SICK official product reference for article 6028974 |
| manufacturer part number | UM18-51115 |
| official source evidence | Exact manufacturer-owned URL found by targeted official search; product identifier matched in official URL/page/search result. No stock, warranty, authorization, or compatibility claim inferred. |
| verified spec source url | https://www.sick.com/us/en/p/pn6028974 |
| global residual cleanup at | 2026-05-20T14:17:56.541Z |
| official source verified at | 2026-05-20T16:19:03.977Z |
| sick factfinder verified at | 2026-05-21T13:03:13.960Z |
| verified spec field sources | [object Object] |
| official product description | Manufacturer-owned SICK product URL generated from exact article/order code 6028974. |
| global residual cleanup method | a_plus_global_residual_content_cleanup_v1 |
| verified spec conflicts skipped | [object Object], [object Object] |
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3External price and availability observations are RFQ context, not guaranteed stock or final sale price.
Source 1Source 2Source 3Raw supplier/import notes are preserved for manager review before quote approval.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.
IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.
Use Wenglor ZAB02NN01 (sensor or switch component) for machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type, connector, and supply voltage with buyer documents before quote approval.
Use Wenglor IW120SE65UA3 (sensor or switch component) for machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type, connector, and supply voltage with buyer documents before quote approval.
Use ZBE-101 (sensor or switch component) for machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type, connector, and supply voltage with buyer documents before quote approval.
Use ZBE-102 (sensor or switch component) for machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type, connector, and supply voltage with buyer documents before quote approval.