Source 1Source 2Source 3Schneider Electric / TPRST009
Use Schneider Electric TPRST009 (relay / contactor component) for drive, servo, and motion-axis maintenance; confirm power rating, feedback or control protocol, firmware/revision, and mechanical fit with buyer documents before quote approval.
Schneider Electric TPRST009 is listed as a Industrial Components relay / contactor component record for SKU-led sourcing. The current record shows condition to confirm, requires price confirmation, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.
Schneider Electric TPRST009 is maintained as motor starter TeSys island 15a at ac1 9a at ac3 4kw 5hp dol type with manufacturer-owned source evidence attached to the record. The page is intended for procurement and maintenance teams that need a cleaner alternative to raw import rows: exact part identity, source trail, category fit, and RFQ inputs stay visible before a quote is requested. Structured specifications are added only when a source confirms them, so missing electrical or mechanical details remain buyer inputs instead of assumptions. Stock, authorization, warranty, lead time, and final compatibility are not implied. Confirm motor or drive series, voltage and power rating, feedback or control protocol, firmware/revision constraints, quantity, condition, and destination country before approving a replacement or purchase.
| series | TPRST009 family candidate |
|---|---|
| function | control-circuit switching, signaling, or motor control |
| descriptor | industrial spare part |
| source brand | Schneider Electric |
| product family | TPRST009 family candidate |
| schneider range | TeSys |
| source confidence | high |
| supplier keywords | Schneider Electric, Пускатель TPRST009, Schneider, Electric, Пускатель, TPRST009 |
| validated category | Drives & Motion |
| category confidence | high |
| verified spec notes | Worker EL parsed exact Schneider Electric product-detail JSON characteristics from a manufacturer-owned product page. No price, stock, warranty, authorization, or lead-time claim is inferred. |
| official product url | https://www.se.com/us/en/product/TPRST009/motor-starter-tesys-island-15a-at-ac1-9a-at-ac3-4kw-5hp-dol-type/ |
| verified spec fields | manufacturer_part_number, official_product_description, official_product_title, official_product_url, official_source_brand, official_source_verified_at, schneider_conventional_free_air_thermal_current, schneider_device_presentation, schneider_device_short_name, schneider_function_available, schneider_motor_power_kw, schneider_motor_starter_type, schneider_poles_description, schneider_product_compatibility, schneider_product_name, schneider_product_or_component_type, schneider_range, schneider_rated_impulse_withstand_voltage, schneider_rated_insulation_voltage, schneider_rated_operational_current, schneider_rated_operational_voltage, schneider_thermal_protection_adjustment_range |
| verified spec method | worker_el_schneider_product_detail_recovery_wave |
| official source brand | Schneider Electric |
| alternate part numbers | TeSys island |
| official product title | TPRST009 - Motor starter, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp, DOL type |
| schneider product name | TeSys island |
| manufacturer part number | TPRST009 |
| marketing content source | official_product_title |
| schneider motor power kw | 2.2 kW at 230 V 50 Hz (AC-3); 4 kW at 380...415 V 50 Hz (AC-3); 4 kW at 440 V 50 Hz (AC-3); 5.5 kW at 500 V 50 Hz (AC-3); 5.5 kW at 690 V 50 Hz (AC-3) |
| verified spec source url | https://www.se.com/us/en/product/TPRST009/motor-starter-tesys-island-15a-at-ac1-9a-at-ac3-4kw-5hp-dol-type/ |
| manufacturer product name | Motor Starter Tesys Island 15a At Ac1 9a At Ac3 4kw 5hp Dol Type |
| official spec reviewed at | 2026-05-22T18:37:25.344Z |
| normalized category signal | Relays/Contactors |
| official source verified at | 2026-05-22T18:37:25.343Z |
| official spec review method | worker_el_schneider_product_detail_recovery_wave |
| official spec review reason | Schneider official parser exhausted: product pages/sources are official, but the current parser did not expose enough exact structured fields for verified_specs without inference. |
| official spec review status | verified_specs |
| schneider device short name | TPRST |
| schneider poles description | 3P 3 NO |
| verified spec field sources | [object Object] |
| official product description | TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setti |
| schneider function available | Upstream voltage presence detection; Electrical line and load protection; Power and energy monitoring when connected with TPRVM voltage module |
| schneider motor starter type | Direct on line |
| marketing content enriched at | 2026-05-20T06:54:49.220Z |
| schneider device presentation | Direct starter connected to an automation controller through a bus coupler; Operational only when connected to a bus coupler |
| official spec review source url | https://www.se.com/us/en/product/TPRST009/motor-starter-tesys-island-15a-at-ac1-9a-at-ac3-4kw-5hp-dol-type/ |
| schneider product compatibility | TPRBC bus coupler; TPRVM voltage interface module |
| official spec review source count | 1 |
| schneider rated insulation voltage | 690 V IEC 60947-4-1; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1 |
| schneider product or component type | Motor starter |
| schneider rated operational current | 9 A (at <122 deg F (50 deg C)) at <= 440 V AC-3; 15 A (at <122 deg F (50 deg C)) at <= 440 V AC-1 |
| schneider rated operational voltage | <= 690 V AC 47...63 Hz |
| schneider rated impulse withstand voltage | 6 kV IEC 60947-1 |
| schneider thermal protection adjustment range | 0.189 A |
| schneider conventional free air thermal current | 15 A (at 122 deg F (50 deg C)) |
| worker el schneider product detail recovery reviewed at | 2026-05-22T18:37:25.344Z |
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3External price and availability observations are RFQ context, not guaranteed stock or final sale price.
Source 1Source 2Source 3Raw supplier/import notes are preserved for manager review before quote approval.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.
IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.
Allen Bradley 700-HK32A2-4L supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
Allen Bradley 700-HK32Z24-4 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
Allen Bradley 700-HK36Z24-4 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SAM250000R1010 supports control-cabinet protection, feeder maintenance, and breaker/fuse replacement; confirm rated current, voltage rating, breaking capacity and USD RFQ context before approval.