3 records
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3Schneider Electric / LRE07
Use Schneider Electric LRE07 (control relay) for control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating, terminal style, and accessories with buyer documents before quote approval.
Schneider Electric LRE07 is listed as a Electrical Control control relay record for SKU-led sourcing. The current record shows condition to confirm, requires price confirmation, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.
Schneider Electric LRE07 is maintained as thermal overload relayeasy TeSys protect1 62 5aclass 10afor lc1e0638 with manufacturer-owned source evidence attached to the record. The page is intended for procurement and maintenance teams that need a cleaner alternative to raw import rows: exact part identity, source trail, category fit, and RFQ inputs stay visible before a quote is requested. Structured specifications are added only when a source confirms them, so missing electrical or mechanical details remain buyer inputs instead of assumptions. Stock, authorization, warranty, lead time, and final compatibility are not implied. Confirm coil voltage, contact configuration, load rating, mounting/socket requirements, quantity, condition, and destination country before approving a replacement or purchase.
| series | LRE07 family candidate |
|---|---|
| function | control-circuit switching, signaling, or motor control |
| descriptor | control relay |
| source brand | Schneider Electric |
| product family | LRE07 family candidate |
| schneider range | Easy TeSys |
| schneider colour | Grey (RAL 7011) |
| source confidence | high |
| supplier keywords | Schneider Electric, Реле перегрузки тепловое LRE07, Schneider, Electric, Реле, перегрузки, тепловое, LRE07 |
| validated category | Relays/Contactors |
| category confidence | high |
| verified spec notes | Worker EM parsed exact Schneider Electric product-detail JSON characteristics from a manufacturer-owned product page. No price, stock, warranty, authorization, or lead-time claim is inferred. |
| official product url | https://www.se.com/au/en/product/LRE07/thermal-overload-relayeasy-tesys-protect1-6-2-5aclass-10a/ |
| verified spec fields | manufacturer_part_number, official_product_description, official_product_title, official_product_url, official_source_brand, official_source_verified_at, schneider_colour, schneider_device_short_name, schneider_mechanical_robustness, schneider_mounting_support, schneider_network_frequency, schneider_network_type, schneider_phase_failure_sensitivity, schneider_product_compatibility, schneider_product_or_component_type, schneider_range, schneider_range_of_product, schneider_relay_application, schneider_signalling_function, schneider_thermal_overload_class, schneider_thermal_protection_adjustment_range, schneider_tripping_threshold |
| verified spec method | worker_em_schneider_product_detail_second_wave |
| official source brand | Schneider Electric |
| alternate part numbers | Easy TeSys Protect |
| official product title | LRE07 - Thermal overload relay,Easy TeSys Protect,1.6...2.5A,class 10A |
| schneider network type | AC |
| manufacturer part number | LRE07 |
| marketing content source | official_product_title |
| verified spec source url | https://www.se.com/au/en/product/LRE07/thermal-overload-relayeasy-tesys-protect1-6-2-5aclass-10a/ |
| manufacturer product name | Thermal Overload Relayeasy Tesys Protect1 62 5aclass 10afor Lc1e0638 |
| official spec reviewed at | 2026-05-22T18:45:11.982Z |
| normalized category signal | Relays/Contactors |
| schneider mounting support | Under contactor; Plate, with specific accessories; Rail, with specific accessories |
| schneider range of product | Easy TeSys Protect |
| official source verified at | 2026-05-22T18:45:11.982Z |
| official spec review method | worker_em_schneider_product_detail_second_wave |
| official spec review reason | Schneider official parser exhausted: product pages/sources are official, but the current parser did not expose enough exact structured fields for verified_specs without inference. |
| official spec review status | verified_specs |
| schneider device short name | LRE |
| schneider network frequency | 50...60 Hz |
| schneider relay application | Motor protection |
| verified spec field sources | [object Object] |
| official product description | The LRE relay is a differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L. Its thermal setting range is 1.6-2.5A 50/60Hz and the tripping class is 10A conforming to IEC 60947-4-1. It can be dire |
| schneider tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| marketing content enriched at | 2026-05-20T06:56:34.449Z |
| schneider signalling function | Relay trip indicator |
| official spec review source url | https://www.se.com/au/en/product/LRE07/thermal-overload-relayeasy-tesys-protect1-6-2-5aclass-10a/ |
| schneider mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7; Vibrations: 3 GN conforming to IEC 60068-2-6 |
| schneider product compatibility | LC1E06...38 |
| schneider thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| official spec review source count | 1 |
| schneider phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
| schneider product or component type | Differential thermal overload relay |
| schneider thermal protection adjustment range | 1.62.5 A |
| worker em schneider product detail second reviewed at | 2026-05-22T18:45:11.982Z |
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3External price and availability observations are RFQ context, not guaranteed stock or final sale price.
Source 1Source 2Source 3Raw supplier/import notes are preserved for manager review before quote approval.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.
IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.
ABB 1SBL141001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL181001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL237001R1100 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL241001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.