3 records
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3Schneider Electric / LRD3361
Use Schneider Electric LRD3361 (control relay) for control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating, terminal style, and accessories with buyer documents before quote approval.
Schneider Electric LRD3361 is listed as a Electrical Control control relay record for SKU-led sourcing. The current record shows new, has a verified USD price reference, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.
Schneider Electric LRD3361 is maintained as thermal overload relay TeSys deca 55 70 a class 10a with manufacturer-owned source evidence attached to the record. The page is intended for procurement and maintenance teams that need a cleaner alternative to raw import rows: exact part identity, source trail, category fit, and RFQ inputs stay visible before a quote is requested. Structured specifications are added only when a source confirms them, so missing electrical or mechanical details remain buyer inputs instead of assumptions. Stock, authorization, warranty, lead time, and final compatibility are not implied. Confirm coil voltage, contact configuration, load rating, mounting/socket requirements, quantity, condition, and destination country before approving a replacement or purchase.
| series | TeSys |
|---|---|
| function | control-circuit switching, signaling, or motor control |
| descriptor | control relay |
| source brand | Schneider Electric |
| product family | TeSys |
| schneider range | TeSys |
| compatible system | TeSys motor control family |
| source confidence | high |
| supplier keywords | Schneider Electric, Реле перегрузки тепловое LRD3361, Schneider, Electric, Реле, перегрузки, тепловое, LRD3361 |
| validated category | Relays/Contactors |
| category confidence | high |
| verified spec notes | Worker EM parsed exact Schneider Electric product-detail JSON characteristics from a manufacturer-owned product page. No price, stock, warranty, authorization, or lead-time claim is inferred. |
| official product url | https://www.se.com/us/en/product/LRD3361/tesys-deca-thermal-overload-relay-55-to-70-a-class-10a-for-lc1d80-and-lc1d95/ |
| verified spec fields | manufacturer_part_number, official_product_description, official_product_title, official_product_url, official_source_brand, official_source_verified_at, schneider_auxiliary_contact_composition, schneider_conventional_free_air_thermal_current, schneider_device_short_name, schneider_mounting_support, schneider_network_frequency, schneider_network_type, schneider_permissible_current, schneider_product_compatibility, schneider_product_name, schneider_product_or_component_type, schneider_range, schneider_rated_insulation_voltage, schneider_relay_application, schneider_thermal_overload_class, schneider_thermal_protection_adjustment_range, schneider_tripping_threshold |
| verified spec method | worker_em_schneider_product_detail_second_wave |
| official source brand | Schneider Electric |
| alternate part numbers | TeSys Deca overload relays |
| official product title | LRD3361 - TeSys Deca, thermal overload relay, 55 to 70 A, class 10A, for LC1D80 and LC1D95 |
| schneider network type | DC; AC |
| schneider product name | TeSys LRD; TeSys Deca |
| manufacturer part number | LRD3361 |
| marketing content source | official_product_title |
| verified spec source url | https://www.se.com/us/en/product/LRD3361/tesys-deca-thermal-overload-relay-55-to-70-a-class-10a-for-lc1d80-and-lc1d95/ |
| manufacturer product name | Thermal Overload Relays Tesys Deca 55 70 A Class 10a |
| official spec reviewed at | 2026-05-22T18:45:11.479Z |
| normalized category signal | Relays/Contactors |
| schneider mounting support | Plate, with specific accessories; Rail, with specific accessories; Under contactor |
| official source verified at | 2026-05-22T18:45:11.479Z |
| official spec review method | worker_em_schneider_product_detail_second_wave |
| official spec review reason | Schneider official parser exhausted: product pages/sources are official, but the current parser did not expose enough exact structured fields for verified_specs without inference. |
| official spec review status | verified_specs |
| schneider device short name | LRD |
| schneider network frequency | 0...400 Hz |
| schneider relay application | Motor protection |
| verified spec field sources | [object Object] |
| official product description | TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 80 amp through 95 amp TeSys D contactors. These differential thermal overload relays detect over current |
| schneider tripping threshold | 1.14 +/- 0.06 Ir IEC 60947-4-1 |
| marketing content enriched at | 2026-05-20T06:56:29.911Z |
| schneider permissible current | 0.72 A 500 V AC-15 signalling circuit; 0.06 A 440 V DC-13 signalling circuit |
| official spec review source url | https://www.se.com/us/en/product/LRD3361/tesys-deca-thermal-overload-relay-55-to-70-a-class-10a-for-lc1d80-and-lc1d95/ |
| schneider product compatibility | LC1D95; LC1D80 |
| schneider thermal overload class | Class 10A IEC 60947-4-1 |
| official spec review source count | 1 |
| schneider rated insulation voltage | Power circuit 1000 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL |
| schneider product or component type | Differential thermal overload relay |
| schneider auxiliary contact composition | 1 NO + 1 NC |
| schneider thermal protection adjustment range | 5570 A |
| schneider conventional free air thermal current | 5 A signalling circuit |
| worker em schneider product detail second reviewed at | 2026-05-22T18:45:11.479Z |
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3External price and availability observations are RFQ context, not guaranteed stock or final sale price.
Source 1Source 2Source 3Raw supplier/import notes are preserved for manager review before quote approval.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.
IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.
ABB 1SBL141001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL181001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL237001R1100 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SBL241001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.