IndGearIndustrial automation parts, verified before order approval.Request quote
LRD12catalog record

Schneider Electric / LRD12

Schneider Electric LRD12 thermal overload relaytesys deca5 58a1no+1ncclass 10ascrew clamp

Use Schneider Electric LRD12 (control relay) for control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating, terminal style, and accessories with buyer documents before quote approval.

Brand
Schneider Electric
SKU
LRD12
Category
Electrical Control
Condition
new missing box
Price status
verified
Sources
8 records

Product overview

Schneider Electric LRD12 is listed as a Electrical Control control relay record for SKU-led sourcing. The current record shows new missing box, has a verified USD price reference, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.

Technical notes

Schneider Electric LRD12 is maintained as thermal overload relaytesys deca5 58a1no+1ncclass 10ascrew clamp with manufacturer-owned source evidence attached to the record. The page is intended for procurement and maintenance teams that need a cleaner alternative to raw import rows: exact part identity, source trail, category fit, and RFQ inputs stay visible before a quote is requested. Structured specifications are added only when a source confirms them, so missing electrical or mechanical details remain buyer inputs instead of assumptions. Stock, authorization, warranty, lead time, and final compatibility are not implied. Confirm coil voltage, contact configuration, load rating, mounting/socket requirements, quantity, condition, and destination country before approving a replacement or purchase.

Key features

  • Part number: LRD12
  • Manufacturer: Schneider Electric
  • Source-backed name: Thermal Overload Relaytesys Deca5 58a1no+1ncclass 10ascrew Clamp
  • Category: Relays/Contactors
  • Type: thermal overload relaytesys deca5 58a1no+1ncclass 10ascrew clamp
  • Final price and terms require RFQ confirmation

Applications

  • control cabinet switching
  • machine interlock circuits
  • maintenance relay or contactor replacement

Verified specifications

seriesTeSys
functioncontrol-circuit switching, signaling, or motor control
descriptorcontrol relay
source brandSchneider Electric
product familyTeSys
schneider rangeTeSys; TeSys Deca
compatible systemTeSys motor control family
source confidencehigh
supplier keywordsSchneider Electric, Реле перегрузки тепловое LRD12, Schneider, Electric, Реле, перегрузки, тепловое, LRD12
validated categoryRelays/Contactors
category confidencehigh
verified spec notesWorker EM parsed exact Schneider Electric product-detail JSON characteristics from a manufacturer-owned product page. No price, stock, warranty, authorization, or lead-time claim is inferred.
official product urlhttps://www.se.com/us/en/product/LRD12/tesys-deca-thermal-overload-relay-5-5-to-8-a-class-10a/
verified spec fieldsmanufacturer_part_number, official_product_description, official_product_title, official_product_url, official_source_brand, official_source_verified_at, schneider_auxiliary_contact_composition, schneider_conventional_free_air_thermal_current, schneider_device_short_name, schneider_mounting_support, schneider_network_frequency, schneider_network_type, schneider_permissible_current, schneider_product_compatibility, schneider_product_name, schneider_product_or_component_type, schneider_range, schneider_rated_insulation_voltage, schneider_relay_application, schneider_thermal_overload_class, schneider_thermal_protection_adjustment_range, schneider_tripping_threshold
verified spec methodworker_em_schneider_product_detail_second_wave
official source brandSchneider Electric
alternate part numbersTeSys Deca overload relays
official product titleLRD12 - TeSys Deca, thermal overload relay, 5.5 to 8 A, class 10A
schneider network typeDC; AC
schneider product nameTeSys LRD; TeSys Deca
manufacturer part numberLRD12
marketing content sourceofficial_product_title
verified spec source urlhttps://www.se.com/us/en/product/LRD12/tesys-deca-thermal-overload-relay-5-5-to-8-a-class-10a/
manufacturer product nameThermal Overload Relaytesys Deca5 58a1no+1ncclass 10ascrew Clamp
official spec reviewed at2026-05-22T18:45:11.072Z
normalized category signalRelays/Contactors
schneider mounting supportPlate, with specific accessories; Rail, with specific accessories; Under contactor
official source verified at2026-05-22T18:45:11.071Z
official spec review methodworker_em_schneider_product_detail_second_wave
official spec review reasonSchneider official parser exhausted: product pages/sources are official, but the current parser did not expose enough exact structured fields for verified_specs without inference.
official spec review statusverified_specs
schneider device short nameLRD
schneider network frequency0...400 Hz
schneider relay applicationMotor protection
verified spec field sources[object Object]
official product descriptionTeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents
schneider tripping threshold1.14 +/- 0.06 Ir IEC 60947-4-1
marketing content enriched at2026-05-20T06:56:22.699Z
schneider permissible current1.5 A 240 V AC-15 signalling circuit; 0.1 A 250 V DC-13 signalling circuit
official spec review source urlhttps://www.se.com/us/en/product/LRD12/tesys-deca-thermal-overload-relay-5-5-to-8-a-class-10a/
schneider product compatibilityLC1D18; LC1D25; LC1D32; LC1D12; LC1D09; LC1D38
schneider thermal overload classClass 10A IEC 60947-4-1
official spec review source count1
schneider rated insulation voltagePower circuit 600 V CSA; Power circuit 600 V UL; Power circuit 690 V IEC 60947-4-1
schneider product or component typeDifferential thermal overload relay
schneider auxiliary contact composition1 NO + 1 NC
schneider thermal protection adjustment range5.58 A
schneider conventional free air thermal current5 A signalling circuit
worker em schneider product detail second reviewed at2026-05-22T18:45:11.072Z
Source context

References used before quote approval

Official manufacturer reference

3 records

Technical model data should be checked against manufacturer material where available.

Source 1Source 2Source 3
Marketplace observation

3 records

External price and availability observations are RFQ context, not guaranteed stock or final sale price.

Source 1Source 2Source 3
Internal import note

To verify

Raw supplier/import notes are preserved for manager review before quote approval.

FAQ

Is Schneider Electric LRD12 available for immediate shipment?

Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.

Can I request used or refurbished condition?

Yes. Include required condition and quantity in the RFQ so the team can verify available options.

Is this an authorized distributor page?

No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.

RFQ control path

Turn an exact SKU into an approved purchase path.

IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.

  1. 01Submit SKU / BOMExact model, quantity, condition, destination
  2. 02Verify sourceSupplier signal, condition, references
  3. 03Review quoteUSD price, lead time, warranty terms
  4. 04Approve orderFinal confirmation before purchase
Quote-only sourcingRequest a USD quote
Related products

Same brand, category, or product type

ABBverified
1SBL141001R80101SBL141001R8010

ABB 1SBL141001R8010 Relay or Contactor Component

ABB 1SBL141001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.

Category
Electrical Control
Condition
new
Sources
6
Route
RFQ review
From $150.46 USDRequest a USD quote
ABBverified
1SBL181001R80101SBL181001R8010

ABB 1SBL181001R8010 Relay or Contactor Component

ABB 1SBL181001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.

Category
Electrical Control
Condition
new
Sources
7
Route
RFQ review
From $49.87 USDRequest a USD quote
ABBverified
1SBL237001R11001SBL237001R1100

ABB 1SBL237001R1100 Relay or Contactor Component

ABB 1SBL237001R1100 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.

Category
Electrical Control
Condition
never used original packaging
Sources
7
Route
RFQ review
From $256 USDRequest a USD quote
ABBverified
1SBL241001R80101SBL241001R8010

ABB 1SBL241001R8010 Relay or Contactor Component

ABB 1SBL241001R8010 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.

Category
Electrical Control
Condition
new
Sources
6
Route
RFQ review
From $35.98 USDRequest a USD quote