3 records
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3IFM / LK8123
IFM LK8123 supports machine sensing, detection circuits, and replacement sensor sourcing; confirm sensing principle, range, output type and USD RFQ context before approval.
IFM LK8123 is listed as a Industrial Components level sensor record for SKU-led sourcing. The current record shows new, has a verified USD price reference, and must still go through RFQ review so source, condition, warranty, and shipping terms are confirmed before order approval.
IFM LK8123 is maintained as a level sensor for machine sensing, detection circuits, and replacement sensor sourcing. It is grouped with ifm level sensor family records so buyers can compare like-for-like spares instead of treating it as an anonymous import line. The card is treated as rich because source-backed structured data supports the identity and specification depth. Current structured facts include output type switching signal; IO-Link; PNP / NPN; normally open / closed; (configurable); communication protocol IO-Link; voltage 18...30 V DC; connector 1 x M12; coding: A; Contacts: gold-plated. USD price context is available as a reference observation, while final commercial terms still require RFQ confirmation. Before approval, confirm sensing principle, range, output type, connector, supply voltage, quantity, preferred condition, and destination country. The record does not claim authorized distribution, guaranteed stock, warranty, lead time, or final compatibility without operations review.
| series | ifm level sensor family |
|---|---|
| weight | 372.6 g |
| voltage | 18...30 V DC |
| function | level measurement |
| material | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PP; PA; TPV |
| connector | 1 x M12; coding: A; Contacts: gold-plated |
| descriptor | industrial spare part |
| dimensions | dia. 16 mm |
| output type | switching signal; IO-Link; PNP / NPN; normally open / closed; (configurable) |
| sensing type | capacitive |
| source brand | IFM |
| product family | ifm level sensor family |
| digital outputs | 4 |
| ifm verified at | 2026-05-21T08:58:11.057Z |
| protection rating | IP67 |
| source confidence | high |
| supplier keywords | IFM, Уровнемер емкостной LK8123 \ LK0472B-B-00KVPKG/US, Уровнемер, емкостной, LK8123, LK0472B-B-00KVPKG/US |
| temperature range | 0...60 C |
| medium temperature | 0...35; (with climate tube E43101: 35...60 C) |
| validated category | Sensors |
| current consumption | < 50 mA |
| product designation | LK0472B-B-00KVPKG / US |
| verified spec notes | IFM structured fields were parsed only from exact ifm-owned productdetail and datasheetTab JSON endpoints; no stock, warranty, authorization, lead-time, or final compatibility claim is inferred. |
| official product url | https://www.ifm.com/us/en/product/LK8123 |
| verified spec fields | alternate_part_numbers, communication_protocol, connector, current_consumption, digital_outputs, dimensions, manufacturer_part_number, material, medium_temperature, official_datasheet_pdf_url, official_product_url, official_short_description, output_type, product_designation, protection_rating, sensing_type, storage_temperature_range, temperature_range, validated_category, voltage, weight |
| verified spec method | ifm_official_datasheet_parser_v1 |
| official source brand | IFM |
| alternate part numbers | Electronic level sensor, LK0472B-B-00KVPKG/US, LK0472B-B-00KVPKG / US |
| communication protocol | IO-Link |
| official product title | LK8123 - Electronic level sensor - ifm |
| manufacturer part number | LK8123 |
| verified spec source url | https://media.ifm.com/dam/8a6feb9b-ad0b-452d-9466-0f10eee8a4bf/Original/LK8123-03_EN-US.pdf |
| manufacturer product name | LK8123 |
| storage temperature range | -25...80 C |
| official datasheet pdf url | https: / / media.ifm.com / dam / 8a6feb9b-ad0b-452d-9466-0f10eee8a4bf / Original / LK8123-03_EN-US.pdf |
| official short description | Electronic level sensor; PNP / NPN; switching signal; IO-Link; Probe length L 472 mm; Medium temperature (Coolants / water / oil) 0...35; (with climate tube E43101: 35...60 C) C / 0...35; (with climate tube E43101 35...60 C) C / 0...70 C; Connector |
| official source verified at | 2026-05-21T13:29:22.315Z |
| verified spec field sources | [object Object] |
| official product description | For the reliable level control in tanks and containers, Suitable for water, oils and coolants, Clearly visible numerical display |
| verified spec conflicts skipped | [object Object] |
Technical model data should be checked against manufacturer material where available.
Source 1Source 2Source 3External price and availability observations are RFQ context, not guaranteed stock or final sale price.
Source 1Source 2Source 3Raw supplier/import notes are preserved for manager review before quote approval.
Availability must be confirmed during RFQ because source, condition, stock location, and destination can change.
Yes. Include required condition and quantity in the RFQ so the team can verify available options.
No unsupported authorization claim is made here. IndGear operates as an independent supplier marketplace unless specific authorization is verified.
IndGear reviews source, condition, lead time, warranty terms, and USD quote context before your team commits to the order.
Allen Bradley 700-HK32A2-4L supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
Allen Bradley 700-HK32Z24-4 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
Allen Bradley 700-HK36Z24-4 supports control-cabinet switching, motor-starter service, and relay replacement; confirm coil/control voltage, contact configuration, load rating and USD RFQ context before approval.
ABB 1SAM250000R1010 supports control-cabinet protection, feeder maintenance, and breaker/fuse replacement; confirm rated current, voltage rating, breaking capacity and USD RFQ context before approval.